Abstract
Gas leak infrared imaging detection technology has become one of the most effective means to detect gas leaks. We propose a novel MRGC (minimum resolvable gas concentration) model that is suitable for evaluating the performance of passive GLIIDSs (gas leak infrared imaging detection systems). An MRGC equivalent calculation method and a direct MRGC measurement method based on the MRTD (minimum resolvable temperature difference) model are also proposed. The MRGC measurement system is designed and built. The measured and calculated results are in good agreement, which verifies the MRGC model's correctness and demonstrates the effectiveness of the MRGC performance evaluation method.
| Original language | English |
|---|---|
| Pages (from-to) | A1701-A1712 |
| Journal | Optics Express |
| Volume | 22 |
| Issue number | 25 |
| DOIs | |
| Publication status | Published - 15 Dec 2014 |
| Externally published | Yes |