T1 - Inverse fitting direct absorption spectroscopy Technology
T2 - Simplified implementation and enhanced performance
AU - Sun, Jiachen
AU - Wang, Fupeng
AU - Chang, Jun
AU - Zhang, Lin
AU - Shao, Jiankun
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2024/11/5
Y1 - 2024/11/5
N2 - The conventional direct absorption spectroscopy (DAS) technique has been plagued by the difficulty of obtaining accurate baseline, which is caused by photoelectric drift and the absence of non-absorbing regions in the transmitted light intensity signal. An inverse fitting direct absorption spectroscopy (IF-DAS) technique has been proposed to address this difficulty. The technique leverages the intrinsic nonlinear intensity response of tunable lasers to achieve baseline-free concentration measurements. It offers the advantages of being straightforward to implement, baseline-free, calibration-free, and resistant to photoelectric signal drift. Its efficacy was validated using an example under ambient temperature and atmospheric pressure conditions. The performance of the IF-DAS technique was compared with that of the conventional DAS technique through standard experimental tests. The results demonstrate that the IF-DAS technique is less susceptible to fluctuations in light intensity, exhibits superior linearity and accuracy, with an R2 value of 0.99986 and an overall error of less than 2%. This technique shows potential for application in harsh scenarios such as reactive flow fields and long-term engineering applications.
AB - The conventional direct absorption spectroscopy (DAS) technique has been plagued by the difficulty of obtaining accurate baseline, which is caused by photoelectric drift and the absence of non-absorbing regions in the transmitted light intensity signal. An inverse fitting direct absorption spectroscopy (IF-DAS) technique has been proposed to address this difficulty. The technique leverages the intrinsic nonlinear intensity response of tunable lasers to achieve baseline-free concentration measurements. It offers the advantages of being straightforward to implement, baseline-free, calibration-free, and resistant to photoelectric signal drift. Its efficacy was validated using an example under ambient temperature and atmospheric pressure conditions. The performance of the IF-DAS technique was compared with that of the conventional DAS technique through standard experimental tests. The results demonstrate that the IF-DAS technique is less susceptible to fluctuations in light intensity, exhibits superior linearity and accuracy, with an R2 value of 0.99986 and an overall error of less than 2%. This technique shows potential for application in harsh scenarios such as reactive flow fields and long-term engineering applications.
KW - Baseline-free
KW - Calibration-free
KW - Easy-to-implement
KW - Inverse fitting direct absorption spectroscopy
KW - Photoelectric signal drift-resistant
UR - https://www.scopus.com/pages/publications/85196537322
U2 - 10.1016/j.saa.2024.124660
DO - 10.1016/j.saa.2024.124660
M3 - Article
C2 - 38889564
AN - SCOPUS:85196537322
SN - 1386-1425
VL - 320
JO - Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
JF - Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
M1 - 124660