T1 - Influence of timing between magnetic field and fluid flow in a rotary magnetic refrigerator
AU - Li, Zhenxing
AU - Li, Ke
AU - Guo, Xiaohui
AU - Gao, Xinqiang
AU - Dai, Wei
AU - Gong, Maoqiong
AU - Shen, Jun
N1 - Publisher Copyright:
© 2020
PY - 2021/3/25
Y1 - 2021/3/25
N2 - An active magnetic regenerator with magnetic Brayton cycle is adopted in a rotary-magnet type refrigerator. For the performance of the magnetic refrigerator, timing between the magnetic field and fluid flow profiles is important. This paper experimentally studied the influence of timing between magnetic field profile and fluid flow profile on the performance of a rotary magnetic refrigerator. A timing ratio is defined to indicate the relative time lengths of four processes (magnetization, hot blow, demagnetization, cold blow). Under four different timing ratios, the cooling capacity, temperature span, pressure drop and power consumption are experimentally investigated. A no-load temperature span of 19.8 K is achieved at the timing ratio of 1:4:1:4, which is 2.6 K higher than that at the ratio of 1:1:1:1. The results reveal that, at the same utilization factor and frequency, the longer the flow time, the larger the temperature span. The influence of utilization factor and operating frequency are also studied. Though limited by the motor power, a cooling power of 20 W at temperature span of 12.3 K is achieved with the timing ratio of 1:2:1:2 at 0.75 Hz, and the corresponding specific cooling power is approximately 94 W/kg.
AB - An active magnetic regenerator with magnetic Brayton cycle is adopted in a rotary-magnet type refrigerator. For the performance of the magnetic refrigerator, timing between the magnetic field and fluid flow profiles is important. This paper experimentally studied the influence of timing between magnetic field profile and fluid flow profile on the performance of a rotary magnetic refrigerator. A timing ratio is defined to indicate the relative time lengths of four processes (magnetization, hot blow, demagnetization, cold blow). Under four different timing ratios, the cooling capacity, temperature span, pressure drop and power consumption are experimentally investigated. A no-load temperature span of 19.8 K is achieved at the timing ratio of 1:4:1:4, which is 2.6 K higher than that at the ratio of 1:1:1:1. The results reveal that, at the same utilization factor and frequency, the longer the flow time, the larger the temperature span. The influence of utilization factor and operating frequency are also studied. Though limited by the motor power, a cooling power of 20 W at temperature span of 12.3 K is achieved with the timing ratio of 1:2:1:2 at 0.75 Hz, and the corresponding specific cooling power is approximately 94 W/kg.
KW - Active magnetic regenerator
KW - Experimental research
KW - Intermittent operation
KW - Magnetic refrigeration
KW - Timing ratios
UR - http://www.scopus.com/inward/record.url?scp=85100200522&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2020.116477
DO - 10.1016/j.applthermaleng.2020.116477
M3 - Article
AN - SCOPUS:85100200522
SN - 1359-4311
VL - 187
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 116477
ER -