Abstract
The basic model and the experimental measurement method of short-distance time-of-flight absorption spectra for determining the temperature of cold atoms are described. Based on the realization of temperature measurement of cold cesium atoms in a magneto-optical trap, the influences of measurement errors of the three experimental parameters, namely the falling distance h, the initial Gaussian radius σ0 of the cold cloud, and the Gaussian radius σp of probe beam, on the determination of temperature have been analyzed and compared.
| Original language | English |
|---|---|
| Pages (from-to) | 6221-6226 |
| Number of pages | 6 |
| Journal | Wuli Xuebao/Acta Physica Sinica |
| Volume | 57 |
| Issue number | 10 |
| Publication status | Published - Oct 2008 |
| Externally published | Yes |
Keywords
- Short-distance time-of-flight absorption spectra
- Temperature of cold atoms
- Time of flight
Fingerprint
Dive into the research topics of 'Influence of parameter errors on the temperature measurement of cold atoms via short-distance time-of-flight absorption spectra'. Together they form a unique fingerprint.Cite this