Skip to main navigation Skip to search Skip to main content

In-situ visualization of spatiotemporal non-uniform frosting dynamics on refrigerator evaporators under intermittent thermal-moisture shocks

  • Xiaoxia Bai
  • , Yunzheng Zhao
  • , Long Zhang
  • , Xuan Zhang
  • , Teng Xie
  • , Guoqing Wang
  • , Mengjie Song*
  • *Corresponding author for this work
  • Department of Energy and Power Engineering
  • Beijing Institute of Technology
  • School of Architecture and Urban Planning
  • Yunnan University
  • Ltd.

Research output: Contribution to journal › Article › peer-review

Abstract

Intermittent door opening introduces significant thermal and moisture shocks to household refrigerators, severely exacerbating evaporator frosting. However, the dynamic evolution of localized non-uniform frosting under these complex operating conditions remains insufficiently characterized. This study develops a non-invasive in-situ visualization system equipped with anti-condensation technology to quantitatively investigate the spatiotemporal non-uniform frosting characteristics on a fin-and-tube evaporator under periodic door openings. Experimental results reveal that periodic moisture load surges significantly enhance frost accumulation, resulting in a distinct S-shaped frost thickness distribution along the airflow direction. While transverse uniformity within fin rows remains relatively stable, the global longitudinal frost uniformity coefficient (FUC) heavily degrades to 70%–77% under prolonged door opening and high humidity conditions. Furthermore, despite exhibiting thinner individual frost layers, the downstream region with the smallest fin spacing experiences the most severe localized flow-passage constriction, reaching a blockage ratio of 43%–50%. This localized blockage is accompanied by a marked deterioration in system performance, with the air-side pressure drop increasing from less than 7 Pa under the closed-door condition to over 16 Pa under the most severe frosting condition, while the average system power increases by nearly 30%, from 106.32 W to 137.47 W. These findings establish a direct link between spatial frost distribution, geometry-dependent blockage, and refrigerator performance, providing an experimental basis for identifying critical frosting regions and developing zonal and on-demand defrosting strategies.

Original languageEnglish
Article number133155
JournalApplied Thermal Engineering
Volume307
DOIs
Publication statusPublished - Oct 2026
Externally publishedYes

Keywords

  • Door opening
  • In-situ visualization
  • Non-uniform frosting
  • Refrigerator evaporator
  • Thermal-dynamic performance

Fingerprint

Dive into the research topics of 'In-situ visualization of spatiotemporal non-uniform frosting dynamics on refrigerator evaporators under intermittent thermal-moisture shocks'. Together they form a unique fingerprint.

Cite this