@inproceedings{dabba4bb90f34a4d9de2632951019276,
title = "Fast dynamic strain measurement using BOCDA enhanced with injection locking configuration",
abstract = "A novel fast BOCDA system to measure dynamic strain without using lock-in-amplifier is developed, and the accuracy is improved using an injection-locking technique. A 200,000-points/s sampling rate and an 8-cm spatial resolution are firstly achieved.",
author = "Bin Wang and Xinyu Fan and Zuyuan He",
note = "Publisher Copyright: {\textcopyright} OSA 2018 {\textcopyright} 2018 The Author(s); Optical Fiber Sensors, OFS 2018 ; Conference date: 24-09-2018 Through 28-09-2018",
year = "2018",
doi = "10.1364/ofs.2018.tue18",
language = "English",
isbn = "9781943580507",
series = "Optics InfoBase Conference Papers",
publisher = "Optica Publishing Group (formerly OSA)",
booktitle = "Optical Fiber Sensors, OFS 2018",
address = "United States",
}