Abstract
A method for the fast measurement of electron temperature and density with temporal resolution in transient plasma has been implemented by Langmuir probe. The diagnostic system consists of a single Langmuir probe driven by a high frequency sinusoidal voltage. The current and voltage spectrum on the probe were detected synchronously by an oscilloscope with sampling rate being at least 5 times higher than the frequency of sweep voltage. The system has been used to diagnose the transient plasma generated by hypervelocity-impact of LY12 aluminum projectile into LY12 aluminum target.
| Original language | English |
|---|---|
| Pages (from-to) | 375-378 |
| Number of pages | 4 |
| Journal | Journal of Beijing Institute of Technology (English Edition) |
| Volume | 16 |
| Issue number | 3 |
| Publication status | Published - Sept 2007 |
Keywords
- Langmuir probe
- Plasma diagnosis
- Sweep voltage