Abstract
Preliminary experimental investigation is done by means of model tests, trying to understand the characteristics of dust agglomerating on the collecting wall of the electrostatic cyclonic precipitator. Relationship between the behaviors of dust on the wall and the collecting efficiency was discussed. The efficiency of the testing cyclone, when enhanced by electricity, is increased 3%-7%, and the maximal value of the efficiency could achieve 99.6%. When the running time increased, the deposition on the wall was increased too, but the collecting efficiency dropped. The testing model could clean itself when the inlet velocity reached 15 m/s.
| Original language | English |
|---|---|
| Pages (from-to) | 774-777 |
| Number of pages | 4 |
| Journal | Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology |
| Volume | 24 |
| Issue number | 9 |
| Publication status | Published - Sept 2004 |
Keywords
- Collection efficiency
- Electrostatic cyclonic precipitator
- Sediment characteristic