TY - GEN
T1 - Experimental study of remote angiography using vascular interventional robot
AU - Lu, Wang Sheng
AU - Xu, Wuyi
AU - Tian, Zengrnin
AU - Guo, Shuxiang
AU - Gao, Baofeng
AU - Liu, Da
AU - Zhao, Depeng
AU - Wang, Daming
PY - 2013
Y1 - 2013
N2 - Robot technology made rapid development in the medical surgical and remote communication technology promote the development of telemedicine. Vascular interventional robot has become a promising technology. To assess the clinical usefulness, accuracy, and safety of remote angiography, we used vascular interventional robot system. Vascular interventional robot system is designed to complete the remote cerebral angiography surgery. Experts in Japan had controlled the slave part of robot in Beijing through operating the host part of robot, and performed cerebral angiography in dog. The positioning accuracy, usefulness and safety were observed. Animal experiment was successful with no complications. The whole procedure included incubating and angiography of common carotid artery and vertebral artery in both sides, it took 45 minutes. The remote positioning accuracy was 1 mm. The result indicates that remote angiography using vascular interventional robot is reliable and safe. In the future, we think that the remote manipulation will advance collaboration between surgeons, develop sharing of resources, and have good prospect in the field of vascular intervention surgery.
AB - Robot technology made rapid development in the medical surgical and remote communication technology promote the development of telemedicine. Vascular interventional robot has become a promising technology. To assess the clinical usefulness, accuracy, and safety of remote angiography, we used vascular interventional robot system. Vascular interventional robot system is designed to complete the remote cerebral angiography surgery. Experts in Japan had controlled the slave part of robot in Beijing through operating the host part of robot, and performed cerebral angiography in dog. The positioning accuracy, usefulness and safety were observed. Animal experiment was successful with no complications. The whole procedure included incubating and angiography of common carotid artery and vertebral artery in both sides, it took 45 minutes. The remote positioning accuracy was 1 mm. The result indicates that remote angiography using vascular interventional robot is reliable and safe. In the future, we think that the remote manipulation will advance collaboration between surgeons, develop sharing of resources, and have good prospect in the field of vascular intervention surgery.
KW - Animal experiments
KW - Remote angiography
KW - Robotics
KW - Vascular intervention
UR - http://www.scopus.com/inward/record.url?scp=84881495387&partnerID=8YFLogxK
U2 - 10.1109/ICCME.2013.6548274
DO - 10.1109/ICCME.2013.6548274
M3 - Conference contribution
AN - SCOPUS:84881495387
SN - 9781467329699
T3 - 2013 ICME International Conference on Complex Medical Engineering, CME 2013
SP - 383
EP - 387
BT - 2013 ICME International Conference on Complex Medical Engineering, CME 2013
T2 - 2013 7th ICME International Conference on Complex Medical Engineering, CME 2013
Y2 - 25 May 2013 through 28 May 2013
ER -