Skip to main navigation Skip to search Skip to main content

Experimental characterization of needle valve dynamics and bounce control in an outwardly opening hydrogen injector

  • Heping Xiang
  • , Ziman Wang*
  • , Lingxiang Ouyang
  • , Xiaocheng Ge
  • , Tong Liang
  • , Fengting Sun
  • , Haoxuan Li
  • *Corresponding author for this work
  • Beijing Institute of Technology
  • Ltd.
  • China Automotive Engineering Research Institute Corporation

Research output: Contribution to journal › Article › peer-review

Abstract

Precise fuel injection control is critical for realizing the full efficiency and emission potential of hydrogen direct injection engines. The low viscosity and poor lubricity of hydrogen, however, bring unique challenges for injector dynamics, particularly regarding needle valve bounce and its impact on metering accuracy and durability. This paper investigates the needle‑valve dynamics of a solenoid outwardly opening hydrogen injector and evaluates a secondary‑current strategy for controlling post‑closure bounce. By using high‑speed backlit imaging, the needle‑lift profiles, response delays, velocity characteristics, and rebound behavior were measured across a wide range of injection pressures, commanded pulse widths, and back pressures. It was found that increasing injection pressure improves linearity and reduces back‑pressure sensitivity for the injected mass. Under short pulses and low pressure (≤12 bar), the needle does not reach full lift, while under high pressure (≥16 bar), full lift can be achieved easily. Opening velocity increases with increasing pressure, and closing peaks velocity (−1.3 to −1.5 m/s) generally exceeds opening peaks, indicating strong seat impact. Needle bounce is obvious, with amplitude up to 32.8 µm. A secondary‑current strategy with a dwell interval of approximately 200 µs and a second pulse duration of approximately 300 µs reduces bounce amplitude by up to 46%, with the first bounce remaining dominant. Consistent with soft-landing control principles, this suggests reduced impact velocity during seating. However, if the secondary current is applied too late (dwell ≥ 400 µs), it re‑excites the needle after seating and amplifies rebound by 170% (to 88.5 µm). These results demonstrate proper selection of injection pressure and secondary‑current timing can significantly mitigate bounce and improve metering robustness.

Original languageEnglish
Article number141854
JournalFuel
Volume430
DOIs
Publication statusPublished - Mar 2027
Externally publishedYes

Keywords

  • Bounce control
  • Hydrogen injector
  • Needle valve dynamics
  • Secondary current

Fingerprint

Dive into the research topics of 'Experimental characterization of needle valve dynamics and bounce control in an outwardly opening hydrogen injector'. Together they form a unique fingerprint.

Cite this