Abstract
In this research, AISI 304 austenitic stainless steels were efficient treatment using active screen plasma oxy-nitriding technique. The modified layers were characterized by X-ray photoelectron spectroscopy, X-ray diffraction, scanning electron microscopy, transmission electron microscopes, and atomic force microscopy. In addition, the pitting corrosion resistances of untreated and oxy-nitrided samples were analyzed by polarization method in 3.5 wt.% NaCl solution. The results showed that a duplex-layer consisting of a deposition layer and a diffusion layer (including CrN+α phase and nitrogen expanded austenite phase) was generated. Special concern has been given to the formation of an amorphous top layer for the deposition of nano sized oxy-nitrides. It believed that the deposition layer of oxy-nitrides formed on steel surface during active screen plasma oxy-nitriding that lead to improved corrosion resistance of AISI 304 austenitic stainless steel, so that the pitting corrosive attack can be avoided.
| Original language | English |
|---|---|
| Article number | e20170697 |
| Journal | Materials Research |
| Volume | 21 |
| Issue number | 6 |
| DOIs | |
| Publication status | Published - Oct 2018 |
| Externally published | Yes |
Keywords
- Austenitic stainless steel
- Oxy-nitrided
- Pitting corrosion
- XPS
Fingerprint
Dive into the research topics of 'Enhancement of pitting corrosion resistance of austenitic stainless steel through deposition of amorphous/nanocrystalline oxy-nitrided phases by active screen plasma treatment'. Together they form a unique fingerprint.Cite this