Skip to main navigation Skip to search Skip to main content

Effects of failure behavior of typical building components on overpressure evolution and prediction in large-scale confined vented natural gas deflagrations

  • Chinese People's Public Security University
  • Beijing Institute of Technology
  • Sinochem

Research output: Contribution to journal › Article › peer-review

Abstract

The severity of vented natural gas deflagrations in confined spaces is influenced by gas concentration, venting-component failure pressure, and failure mode. Unlike conventional vent panels or rupture membranes, real building components fail through progressive cracking, flexural deformation, or global fracture, and these failure modes can govern double-peak pressure formation. To quantify this effect, experiments were conducted in a 27.39 m3 confined chamber using four venting components: double-layer ordinary framed float glass, a 120 mm lightweight-brick masonry wall, a 115 mm red-brick masonry wall, and double-layer tempered glass, under varying equivalence ratios. A modified Lee model was then developed by incorporating flame-front area correction, turbulent flame speed, equivalence-ratio-dependent heat release, and a criterion for the secondary overpressure peak. The failure overpressures followed the order tempered glass > red-brick wall > lightweight-brick wall > ordinary framed float glass. The pressure response depended not only on component strength and gas concentration but also on the post-failure venting state. Ordinary framed float glass, lightweight-brick masonry wall, and red-brick masonry wall generally produced double-peak pressure histories, whereas tempered glass mainly yielded a single-peak response because global fracture enabled more complete venting. These real-component failure modes were key to reproducing the double-peak structure and improving prediction accuracy. The modified Lee model enhanced the double-peak structure more reliably than the original Lee model and improved the prediction of readily vented components. These results highlight the importance of considering real building-component failure behavior in vented deflagration analysis, rather than idealized vent-panel assumptions, and provide a foundation for overpressure prediction and venting safety design.

Original languageEnglish
Article number142285
JournalEnergy
Volume363
DOIs
Publication statusPublished - 30 Oct 2026
Externally publishedYes

Keywords

  • Deflagration
  • Equivalence ratio
  • Lee model
  • Overpressure peak
  • Venting component

Fingerprint

Dive into the research topics of 'Effects of failure behavior of typical building components on overpressure evolution and prediction in large-scale confined vented natural gas deflagrations'. Together they form a unique fingerprint.

Cite this