Abstract

A diesel-generator can be applied to electric vehicle as an auxiliary power unit (APU). As for its generator, an excitation control method without the brushless exciter parameters is presented. Its first order lag model is obtained through the step response at zero engine speed with the Ziegler-Nichols method. And a PI controller comes out. Then the PI parameters are tuned by simulation and static experiments. At last, the PI excitation regulator is validated by both engine speed and APU voltage regulation experiments on the dSPACE controller. The results are satisfied.

Original languageEnglish
Title of host publication2006 1st IEEE Conference on Industrial Electronics and Applications
DOIs
Publication statusPublished - 2006
Event2006 1st IEEE Conference on Industrial Electronics and Applications, ICIEA 2006 - Singapore, Singapore
Duration: 24 May 200626 May 2006

Publication series

Name2006 1st IEEE Conference on Industrial Electronics and Applications

Conference

Conference2006 1st IEEE Conference on Industrial Electronics and Applications, ICIEA 2006
Country/TerritorySingapore
CitySingapore
Period24/05/0626/05/06