T1 - Determination of titanium oxychloride in refined titanium tetrachloride by infrared spectroscopy
AU - Song, Guang Lin
AU - Luo, Yun Jun
AU - Li, Jin Qing
AU - Li, Zhan Bin
AU - Tan, Hong
PY - 2014
Y1 - 2014
N2 - Determination of TiOCl2 in refined TiCl4 was significant for analysis of its impurities. TiOCl2 could be determined by infrared spectroscopy due to its infrared characteristic spectrum line. However, normal infrared absorption cell was not fit for the sample analysis, because TiCl4 easily reacted with moisture in the air and immediately was hydrolyzed to form highly corrosive hydrochloric acid smoke. The infrared absorption cell with the window film of ZnSe (φ10×1mm, wavenumbers: 7800cm-1~440cm-1) and the glass cell (optical path: 22mm, 12mm, 7mm and 4mm)was assembled and utilized in determination of the TiOCl2 in refined TiCl4 by standard addition method. The detection limit of TiOCl2 was 26.5mg•kg-1, the regression equation was Y=1.0118X, R2=0.9926; With standard addition method, the regression equation of TiOCl2 was Y=1.9400X, R2=0.9940,This infrared absorption device was safe, simple and convenient, easily removable and washable, and re-useable. This method could meet the requirement of determination of TiOCl2 in refined TiCl4.
AB - Determination of TiOCl2 in refined TiCl4 was significant for analysis of its impurities. TiOCl2 could be determined by infrared spectroscopy due to its infrared characteristic spectrum line. However, normal infrared absorption cell was not fit for the sample analysis, because TiCl4 easily reacted with moisture in the air and immediately was hydrolyzed to form highly corrosive hydrochloric acid smoke. The infrared absorption cell with the window film of ZnSe (φ10×1mm, wavenumbers: 7800cm-1~440cm-1) and the glass cell (optical path: 22mm, 12mm, 7mm and 4mm)was assembled and utilized in determination of the TiOCl2 in refined TiCl4 by standard addition method. The detection limit of TiOCl2 was 26.5mg•kg-1, the regression equation was Y=1.0118X, R2=0.9926; With standard addition method, the regression equation of TiOCl2 was Y=1.9400X, R2=0.9940,This infrared absorption device was safe, simple and convenient, easily removable and washable, and re-useable. This method could meet the requirement of determination of TiOCl2 in refined TiCl4.
KW - Infrared spectroscopy
KW - Titanium oxychloride
KW - Titanium tetrachloride
UR - http://www.scopus.com/inward/record.url?scp=84906538917&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMR.997.475
DO - 10.4028/www.scientific.net/AMR.997.475
M3 - Conference contribution
AN - SCOPUS:84906538917
SN - 9783038351900
T3 - Advanced Materials Research
SP - 475
EP - 479
BT - Frontiers of Chemical Engineering, Metallurgical Engineering and Materials III
PB - Trans Tech Publications Ltd.
T2 - 3rd International Conference on Chemical Engineering, Metallurgical Engineering and Metallic Materials, CMMM 2014
Y2 - 20 June 2014 through 21 June 2014
ER -