Abstract
In this study, a biocular system is established and a biocular analysis method is proposed by analyzing the biocular parallax principle to determine the relationship between convergence, dipvergence, azimuth, and elevation. Based on the biocular analysis method, a looped optimization method for reducing biocular parallax is presented. After optimizing the biocular system, convergence of the system is between −6 mrad–6 mrad, and dipvergence is between −1.5 mrad–1.5 mrad. This satisfies the requirements of the human eye for observation with a biocular system. Experimental results are approximately consistent with theoretical analysis. This proves the accuracy of the proposed biocular analysis method.
| Original language | English |
|---|---|
| Pages (from-to) | 7851-7857 |
| Number of pages | 7 |
| Journal | Applied Optics |
| Volume | 58 |
| Issue number | 28 |
| DOIs | |
| Publication status | Published - 1 Oct 2019 |