Abstract

To investigate CO₂ leakage induced by local failure in industrial-scale carbon capture, utilization and storage (CCUS) pipelines, experiments were conducted using a 203.2 m-long loop pipeline with an inner diameter of 323 mm. Local failure was simulated by the instantaneous rupture of a rupture disc. Comparative release tests were then performed for dense-phase and gaseous CO₂ to characterize the pressure-gradient-driven in-pipe response and external dispersion behavior. The results show that, within the first 750 ms after leakage initiation, dense-phase CO₂ exhibited a staged pressure decline with three distinct pressure plateaus. Analysis of the pressure–temperature trajectories indicated that these plateaus corresponded to a high-density single-phase state, a liquid-dominated gas–liquid two-phase state, and a gas-dominated gas–liquid two-phase state, respectively. Under the combined effects of decompression-wave propagation, mass transport, and phase evolution, two pressure plateaus appeared near the release opening, three complete plateaus occurred in the middle section, and only one plateau was observed at the remote end, showing pronounced axial spatial differentiation. For gaseous CO₂, only a short-lived pressure plateau occurred during the initial depressurization stage, after which the pressure declined continuously. Both conditions exhibited a distinct two-stage temperature decrease. During the early stage of leakage, rapid expansion and the Joule–Thomson effect caused a sharp temperature drop near the release opening. The low-temperature region then propagated along the pipeline, while the dense-phase condition was additionally accompanied by significant latent heat exchange associated with phase transition. In the external field, dense-phase CO₂ leakage generated a pronounced near-ground plume, with a horizontal dispersion distance exceeding 70 m and a maximum measured concentration of 1.46%. In contrast, gaseous CO₂ mainly formed a vertically rising columnar jet.

Original languageEnglish
Article number109734
JournalProcess Safety and Environmental Protection
Volume221
DOIs
Publication statusPublished - 15 Nov 2026
Externally publishedYes