Abstract
A current sensorless control strategy of three-phase PWM rectifiers is presented. Double close-loop control method is applied in the system. DC voltage is regulated by the external loop PI regulator. The system can operate at unity power factor by controlling the active and reactive power with two inner loop hysteresis controllers. The input AC current can be reconstructed from the mathematical model of PWM rectifiers in order to eliminating current sensors. The simulation results prove that the system has good performance.
| Original language | English |
|---|---|
| Pages (from-to) | 42-45 |
| Number of pages | 4 |
| Journal | Diangong Jishu Xuebao/Transactions of China Electrotechnical Society |
| Volume | 19 |
| Issue number | 11 |
| Publication status | Published - Nov 2004 |
Keywords
- Current reconstruction
- Current sensorless
- PWM rectifiers
Fingerprint
Dive into the research topics of 'Current sensorless control of three-phase PWM rectifiers'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver