TY - JOUR
T1 - Cough Expired Volume and Cough Peak Flow Rate Estimation Based on GA-BP Method
AU - Ren, Shuai
AU - Niu, Jinglong
AU - Luo, Zihao
AU - Shi, Yan
AU - Cai, Maolin
AU - Luo, Zujin
AU - Yu, Qihui
N1 - Publisher Copyright:
© 2020 Shuai Ren et al.
PY - 2020
Y1 - 2020
N2 - Cough is a respiratory protective behavior for clearing the secretion. The cough process can be characterized by three features which are cough peak flow rate, peak velocity time, and cough expired volume. The cough expired volume (CEV) and the cough peak flow rate (CPFR) are important for medical diagnosis and cough effectiveness assessment. In this study, the CEV and CPFR values of 700 healthy participants were measured and collected by using a portable pulmonary function device. The gender, age, height, weight, and smoking status information of the 700 participants were also collected. Meanwhile, the integration of backpropagation neural network and genetic algorithm (GA-BP) method was developed to estimate CEV and CPFR values. The results showed that the estimation accuracy of GA-BP method exceeds 90%, which indicates that the GA-BP method could be effectively used for CEV and CPFR value estimation. Furthermore, the method proposed in this paper could be useful for medical diagnosis and medical device development.
AB - Cough is a respiratory protective behavior for clearing the secretion. The cough process can be characterized by three features which are cough peak flow rate, peak velocity time, and cough expired volume. The cough expired volume (CEV) and the cough peak flow rate (CPFR) are important for medical diagnosis and cough effectiveness assessment. In this study, the CEV and CPFR values of 700 healthy participants were measured and collected by using a portable pulmonary function device. The gender, age, height, weight, and smoking status information of the 700 participants were also collected. Meanwhile, the integration of backpropagation neural network and genetic algorithm (GA-BP) method was developed to estimate CEV and CPFR values. The results showed that the estimation accuracy of GA-BP method exceeds 90%, which indicates that the GA-BP method could be effectively used for CEV and CPFR value estimation. Furthermore, the method proposed in this paper could be useful for medical diagnosis and medical device development.
UR - https://www.scopus.com/pages/publications/85081163963
U2 - 10.1155/2020/9036369
DO - 10.1155/2020/9036369
M3 - Article
AN - SCOPUS:85081163963
SN - 1076-2787
VL - 2020
JO - Complexity
JF - Complexity
M1 - 9036369
ER -