TY - JOUR
T1 - Complementary configuration and performance comparison of CCHP-ORC system with a ground source heat pump under three energy management modes
AU - Kang, Ligai
AU - Yang, Junhong
AU - An, Qingsong
AU - Deng, Shuai
AU - Zhao, Jun
AU - Li, Zelin
AU - Wang, Yongzhen
N1 - Publisher Copyright:
© 2016 Elsevier Ltd
PY - 2017
Y1 - 2017
N2 - The variation of the end-user load and the constant output of power generation units (PGUs) results in a mismatch between energy supply and demand. To reduce the difference and to avoid an excess output of electricity or heat, a complementary combined cooling, heating and power- organic Rankine cycle system (CCHP-ORC) system with a ground source heat pump is configured. In this study, the CCHP-ORC system, which is operated in thermal demand management (TDM) or electricity demand management mode, is employed to analyze the operational cost (OC), annual total cost (ATC), carbon dioxide emission (CDE), primary energy consumption (PEC) and system efficiency based on a case study of a regional energy system in Sino-Singapore eco-city. Meanwhile, the performance analysis of an improved operational mode is also conducted in this study. Following this mode, the waste heat and electricity imported from grid can be minimized by controlling the operation condition of PGU and ORC with a thermal management controller (TMC-ORC mode). Monthly and annual results in the case study show that the proposed system performed well on OC, CDE and PEC reductions and the ATC are both increased except for the ATC of TMC-ORC mode. However, the total efficiency of TDM is the highest among the three operational modes. Finally, for TMC-ORC mode, sensitivity analysis is performed and results are presented with varying electricity and gas price.
AB - The variation of the end-user load and the constant output of power generation units (PGUs) results in a mismatch between energy supply and demand. To reduce the difference and to avoid an excess output of electricity or heat, a complementary combined cooling, heating and power- organic Rankine cycle system (CCHP-ORC) system with a ground source heat pump is configured. In this study, the CCHP-ORC system, which is operated in thermal demand management (TDM) or electricity demand management mode, is employed to analyze the operational cost (OC), annual total cost (ATC), carbon dioxide emission (CDE), primary energy consumption (PEC) and system efficiency based on a case study of a regional energy system in Sino-Singapore eco-city. Meanwhile, the performance analysis of an improved operational mode is also conducted in this study. Following this mode, the waste heat and electricity imported from grid can be minimized by controlling the operation condition of PGU and ORC with a thermal management controller (TMC-ORC mode). Monthly and annual results in the case study show that the proposed system performed well on OC, CDE and PEC reductions and the ATC are both increased except for the ATC of TMC-ORC mode. However, the total efficiency of TDM is the highest among the three operational modes. Finally, for TMC-ORC mode, sensitivity analysis is performed and results are presented with varying electricity and gas price.
KW - CCHP system
KW - Ground source heat pump
KW - Operational mode
KW - Organic Rankine cycle
KW - Performance analysis
KW - Sensitivity analysis
UR - http://www.scopus.com/inward/record.url?scp=85008315569&partnerID=8YFLogxK
U2 - 10.1016/j.enconman.2016.12.055
DO - 10.1016/j.enconman.2016.12.055
M3 - Article
AN - SCOPUS:85008315569
SN - 0196-8904
VL - 135
SP - 244
EP - 255
JO - Energy Conversion and Management
JF - Energy Conversion and Management
ER -