Skip to main navigation Skip to search Skip to main content

A Tubular Dual-Roller Bending Mechanism Toward Robotic Transurethral Prostate Biopsy

  • Xiao Xiao
  • , Changsheng Li
  • , Xiaoyi Gu
  • , Yusheng Yan
  • , Yifan Wu
  • , Qinghui Wu
  • , Edmund Chiong
  • , Hongliang Ren*
  • *Corresponding author for this work
  • National University of Singapore
  • Southern University of Science and Technology
  • Harbin Engineering University
  • Northwestern University
  • MOH Holdings Pte Ltd.
  • Chinese University of Hong Kong

Research output: Contribution to journalArticlepeer-review

Abstract

Prostate biopsy procedures as a gold standard for early screening of prostate cancer often suffer from multipass needle perforations to irrelevant perineal tissue, high complication risk, and time consumption. To address these challenges, this article proposes a transurethral prostate biopsy robot that can deliver a flexible biopsy needle inside the prostate from different angles and thus obtain tissue samples from multiple locations. Emphasis is on the design and validation of the transurethral prostate biopsy robot with a detailed introduction of the working principle, mechanism modeling, and function testing. Phantom experiments in kiwi fruit puncture experiments and prostate phantom puncture experiments have demonstrated their potential in clinical application. The transurethral biopsy robot features a 7-mm tubular dual-roller bending mechanism together with a compact driver mechanism. The flexible biopsy needle can bend from 16.0$^\circ$ to 55.8$^\circ$ with a translational stroke of 32.5 mm and an overall rotational stroke of 360$^\circ$, which enable coverage a volume of 142.2 mL, more extensive than that of an enlarged prostate. The average angle positioning and overall positioning error are 0.82$^{\circ }$ and 1.2 mm, respectively. It can provide a minimum of 6.3-N puncture force. The proposed transurethral prostate biopsy procedure is a unique inside-out robotic prostate biopsy method, contributing to a safer and less invasive prostate biopsy procedure.

Original languageEnglish
Pages (from-to)2483-2494
Number of pages12
JournalIEEE/ASME Transactions on Mechatronics
Volume26
Issue number5
DOIs
Publication statusPublished - 1 Oct 2021

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bendable biopsy needle
  • robotic prostate biopsy
  • transurethral prostate biopsy

Fingerprint

Dive into the research topics of 'A Tubular Dual-Roller Bending Mechanism Toward Robotic Transurethral Prostate Biopsy'. Together they form a unique fingerprint.

Cite this