Abstract
The rule of charge time of high-voltage circuit in the electronic safety and arming system (ESA) of fuzes is studied. Adopting discrete time-domain method to set up the mathematical model of high-voltage conversion circuit, and analyzing the influence of frequency, duty cycle, primary inductance, different turns ratio parameters how to affect high-voltage convertion circuit charging time. Simulation and experiment results express the mathematical model can reflect the variational trend of actual circuit, and the shortest charge time is 75 ms when the frequency of dynamic signal is 100kHz and the duty cycle 0.55.
| Original language | English |
|---|---|
| Pages (from-to) | 237-239 |
| Number of pages | 3 |
| Journal | Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology |
| Volume | 29 |
| Issue number | 3 |
| Publication status | Published - Mar 2009 |
Keywords
- Charge time
- Discrete time-domain model
- Electronic safety and arming (ESA)
- High-voltage conversion