T1 - A robust data-driven model predictive thermal control for rack-based data center
AU - Li, Yiran
AU - Yang, Chao
AU - Xia, Yuanqing
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2024/12/1
Y1 - 2024/12/1
N2 - Optimizing and controlling of air-cooled data centers cooling systems are essential for reducing energy consumption. However, traditional cooling system control strategies have been proven inadequate due to the thermodynamic processes complexity and the challenge for accurately modeling the thermal behavior of data center (DC). Therefore, a data-driven control method without explicit modeling process is urgently needed. In this paper, a robust data-driven model predictive control (MPC) method for air-cooled rack-based DCs, based on Willems fundamental lemma, is proposed. The methodology is executed in three phases: Firstly, we show that the system is approximately linear time-invariant (LTI) by zonal model method and experiment. Secondly, we propose a data-driven MPC framework for air-cooled rack-based DC. Thirdly, considering the uncertainties caused by disturbances and the nonlinear dynamics, the data-driven MPC approach is tailored as a robust one. Finally, the proposed approach is verified by computational fluid dynamics simulation experiments. This approach ensures the rack-based DC cold aisle temperature to the reference temperature as well as within acceptable limits. The experiment shows that the steady-state error is guaranteed to be less than 2%, with a control accuracy increased by 2.4% compared with the regular MPC. Thus, this method provides an alternative solution for maintaining the reference temperature in air-cooled rack-based DCs by utilizing only input–output data.
AB - Optimizing and controlling of air-cooled data centers cooling systems are essential for reducing energy consumption. However, traditional cooling system control strategies have been proven inadequate due to the thermodynamic processes complexity and the challenge for accurately modeling the thermal behavior of data center (DC). Therefore, a data-driven control method without explicit modeling process is urgently needed. In this paper, a robust data-driven model predictive control (MPC) method for air-cooled rack-based DCs, based on Willems fundamental lemma, is proposed. The methodology is executed in three phases: Firstly, we show that the system is approximately linear time-invariant (LTI) by zonal model method and experiment. Secondly, we propose a data-driven MPC framework for air-cooled rack-based DC. Thirdly, considering the uncertainties caused by disturbances and the nonlinear dynamics, the data-driven MPC approach is tailored as a robust one. Finally, the proposed approach is verified by computational fluid dynamics simulation experiments. This approach ensures the rack-based DC cold aisle temperature to the reference temperature as well as within acceptable limits. The experiment shows that the steady-state error is guaranteed to be less than 2%, with a control accuracy increased by 2.4% compared with the regular MPC. Thus, this method provides an alternative solution for maintaining the reference temperature in air-cooled rack-based DCs by utilizing only input–output data.
KW - Air-cooled system
KW - Historical data
KW - Rack-based DC
KW - Robust data-driven MPC
UR - http://www.scopus.com/inward/record.url?scp=85207059963&partnerID=8YFLogxK
U2 - 10.1016/j.jobe.2024.110877
DO - 10.1016/j.jobe.2024.110877
M3 - Article
AN - SCOPUS:85207059963
SN - 2352-7102
VL - 98
JO - Journal of Building Engineering
JF - Journal of Building Engineering
M1 - 110877
ER -