A novel design of Rogowski coil for measurement of nanosecond-risetime high-level pulsed current

Ruo Yu Han, Wei Dong Ding, Jia Wei Wu, Hai Bin Zhou, Yan Jing, Qiao Jue Liu, You Chuang Chao, Ai Ci Qiu

Research output: Contribution to journalArticlepeer-review

15 Citations (Scopus)

Abstract

In pulsed power systems, pulsed currents with risetimes from nanosecond to microsecond can be effectively measured by self-integrating Rogowski coils. Appropriate design of the structure and the integrating resistor is crucial to the high-frequency response of a coil. In this paper, several novel designs of Rogowski coil's integrating resistors were proposed and tested. Experimental results showed that the optimized coil could response square waves with fronts of ∼1.5 ns and had a sensitivity of ∼0.75 V/kA. The maximal peak current was designed as 100 kA.

Original languageEnglish
Article number035114
JournalReview of Scientific Instruments
Volume86
Issue number3
DOIs
Publication statusPublished - 1 Mar 2015
Externally publishedYes

Fingerprint

Dive into the research topics of 'A novel design of Rogowski coil for measurement of nanosecond-risetime high-level pulsed current'. Together they form a unique fingerprint.