Abstract
In this paper, a new leakage measurement method based on the temperature field and temperature gradient field is proposed for detecting the leakage location and measuring the leakage rate in damaged seal material. First, a heat transfer leakage model is established, which can calculate the leakage rate based on the temperature gradient field near the damaged zone. Second, a finite element model of an infinite plate with a damaged zone is built to calculate the leakage rate, which fits the simulated leakage rate well. Finally, specimens in a tubular rubber seal with different damage shapes are used to conduct the leakage experiment, validating the correctness of this new measurement principle for the leakage rate and the leakage position. The results indicate the feasibility of the leakage measurement method for damaged seal material based on the temperature gradient field from infrared thermography.
| Original language | English |
|---|---|
| Article number | 075203 |
| Journal | Measurement Science and Technology |
| Volume | 29 |
| Issue number | 7 |
| DOIs | |
| Publication status | Published - 25 May 2018 |
| Externally published | Yes |
Keywords
- arbitrary damage shape
- damaged rubber seal
- infrared thermography
- leakage rate
- temperature gradient field
Fingerprint
Dive into the research topics of 'A new leakage measurement method for damaged seal material'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver