TY - JOUR
T1 - Study of Peak-load regulation characteristics of a 1000MWe S-CO2 Coal-fired power plant and a comprehensive evaluation method for dynamic performance
AU - Ma, Teng
AU - Li, Ming Jia
AU - Xue, Xiao Dai
AU - Guo, Jia Qi
AU - Wang, Wen Qi
AU - Jiang, Tao
N1 - Publisher Copyright:
© 2022
PY - 2023/2/25
Y1 - 2023/2/25
N2 - In the new power system with large-scale grid-connection of intermittent new energy, the coal-fired power plants (CFPPs) play an important role of the ballast stone. In the process of grid-connection, CFPPs receive variable load instructions in real time. Higher peak-load regulation capacity and more flexible response for CFPPs are needed to provide a stable support to the power grid. The supercritical carbon dioxide (S-CO2) cycle has better variable working condition performance, which may improve the flexibility of the CFPPs peak-load regulation process. To explore the peak-load regulation characteristics of the S-CO2 CFPP, the variable load characteristics of a tri-compressions double-reheating intercooling (TC-DRH-IC) S-CO2 CFPP under five control methods are studied. Furthermore, a comprehensive evaluation method for the dynamic performance is proposed. First, the dynamic model of the TC-DRH-IC S-CO2 cycle with the modified isentropic efficiency of turbo-machineries, the unsteady flow heat transfer model of heat exchangers and a proportion integration differentiation (PID) controller is established. Second, the peak-load regulation characteristics of the TC-DRH-IC S-CO2 cycle are analyzed. A comprehensive evaluation method of dynamic control performance considering load change rate, dynamic response time, load rate variation range and cycle efficiency is proposed. Finally, the inventory control method is improved, which can improve the cycle efficiency at low loads. The results show that the improved inventory control method has a rapid practical load change rate of about 10%/min and a wide range of variable-load regulation from 10% to 100%. And the cycle efficiency is improved by 3.67% at 50% of the rated power. The S-CO2 CFPP has the potential of flexible peak-load regulation.
AB - In the new power system with large-scale grid-connection of intermittent new energy, the coal-fired power plants (CFPPs) play an important role of the ballast stone. In the process of grid-connection, CFPPs receive variable load instructions in real time. Higher peak-load regulation capacity and more flexible response for CFPPs are needed to provide a stable support to the power grid. The supercritical carbon dioxide (S-CO2) cycle has better variable working condition performance, which may improve the flexibility of the CFPPs peak-load regulation process. To explore the peak-load regulation characteristics of the S-CO2 CFPP, the variable load characteristics of a tri-compressions double-reheating intercooling (TC-DRH-IC) S-CO2 CFPP under five control methods are studied. Furthermore, a comprehensive evaluation method for the dynamic performance is proposed. First, the dynamic model of the TC-DRH-IC S-CO2 cycle with the modified isentropic efficiency of turbo-machineries, the unsteady flow heat transfer model of heat exchangers and a proportion integration differentiation (PID) controller is established. Second, the peak-load regulation characteristics of the TC-DRH-IC S-CO2 cycle are analyzed. A comprehensive evaluation method of dynamic control performance considering load change rate, dynamic response time, load rate variation range and cycle efficiency is proposed. Finally, the inventory control method is improved, which can improve the cycle efficiency at low loads. The results show that the improved inventory control method has a rapid practical load change rate of about 10%/min and a wide range of variable-load regulation from 10% to 100%. And the cycle efficiency is improved by 3.67% at 50% of the rated power. The S-CO2 CFPP has the potential of flexible peak-load regulation.
KW - Dynamic performance evaluation method
KW - Improved inventory control
KW - Peak-load regulation characteristics
KW - TC-DRH-IC S-CO coal-fired power plant
KW - Variable-load control
UR - http://www.scopus.com/inward/record.url?scp=85144506252&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2022.119892
DO - 10.1016/j.applthermaleng.2022.119892
M3 - Article
AN - SCOPUS:85144506252
SN - 1359-4311
VL - 221
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 119892