TY - JOUR
T1 - Hydrogen Enhanced Fatigue Crack Growth Rates in a Ferritic Fe-3wt%Si Alloy
AU - Alvaro, Antonio
AU - Wan, Di
AU - Olden, Vigdis
AU - Barnoush, Afrooz
N1 - Publisher Copyright:
© 2018 The Authors.
PY - 2018
Y1 - 2018
N2 - It is well known that the presence of hydrogen in ferrous materials promotes both static fracture and affect the material fatigue crack growth rates. The latter is often referred to as Hydrogen Enhanced Fatigue Crack Growth Rate (HE-FCGR) which defines the reduction of crack growth resistance of the material under cyclic stresses when hydrogen is present. When it comes to the determination of the life of components exposed to hydrogen it is therefore of paramount importance to establish such hydrogen induced variation in crack speed in the material in order to avoid unexpected catastrophic failures. In this study the fatigue crack growth rate was determined for a Fe-3wt%Si alloy. Compact tension specimens were used to determine the Paris regime of the fatigue crack growth rate curve of the material. Two environmental conditions were investigated: laboratory air and in-situ electrochemically charged hydrogen. Different mechanical conditions, in terms of load ratio (R=0.1 and R=0.5) and test frequency (f=0.1 Hz, 1 Hz and 10 Hz), were used under electrochemically charged hydrogen conditions. The results show that compared to the specimens tested in air, there is a clear detrimental effect of H for the specimens tested in hydrogen, in terms of accelerated crack growth. The strength of the impact of hydrogen in enhancing the fatigue crack growth rates of the Fe-3wt%Si alloy clearly depends on the test conditions. Fractographic investigations were also used to unveil the mechanisms involved in the process leading to accelerate crack growth in presence of hydrogen.
AB - It is well known that the presence of hydrogen in ferrous materials promotes both static fracture and affect the material fatigue crack growth rates. The latter is often referred to as Hydrogen Enhanced Fatigue Crack Growth Rate (HE-FCGR) which defines the reduction of crack growth resistance of the material under cyclic stresses when hydrogen is present. When it comes to the determination of the life of components exposed to hydrogen it is therefore of paramount importance to establish such hydrogen induced variation in crack speed in the material in order to avoid unexpected catastrophic failures. In this study the fatigue crack growth rate was determined for a Fe-3wt%Si alloy. Compact tension specimens were used to determine the Paris regime of the fatigue crack growth rate curve of the material. Two environmental conditions were investigated: laboratory air and in-situ electrochemically charged hydrogen. Different mechanical conditions, in terms of load ratio (R=0.1 and R=0.5) and test frequency (f=0.1 Hz, 1 Hz and 10 Hz), were used under electrochemically charged hydrogen conditions. The results show that compared to the specimens tested in air, there is a clear detrimental effect of H for the specimens tested in hydrogen, in terms of accelerated crack growth. The strength of the impact of hydrogen in enhancing the fatigue crack growth rates of the Fe-3wt%Si alloy clearly depends on the test conditions. Fractographic investigations were also used to unveil the mechanisms involved in the process leading to accelerate crack growth in presence of hydrogen.
KW - Fatigue Crack Growth
KW - Hydrgen Embrittlement
KW - Steel
UR - http://www.scopus.com/inward/record.url?scp=85064632205&partnerID=8YFLogxK
U2 - 10.1016/j.prostr.2018.12.310
DO - 10.1016/j.prostr.2018.12.310
M3 - Conference article
AN - SCOPUS:85064632205
SN - 2452-3216
VL - 13
SP - 1514
EP - 1520
JO - Procedia Structural Integrity
JF - Procedia Structural Integrity
T2 - 22nd European Conference on Fracture, ECF 2018
Y2 - 25 August 2018 through 26 August 2018
ER -