T1 - Energy back-projective composition for 3-D coronary artery reconstruction
AU - Cong, Weijian
AU - Yang, Jian
AU - Liu, Yue
AU - Wang, Yongtian
PY - 2013
Y1 - 2013
N2 - This paper presents a novel energy back-projective composition model (EBPCM) for 3-D reconstruction of the coronary arteries from two mono-plane angiographic images. A major problem with the commonly used parameter deformable model is that the predefined correspondences may become non-strict matching after the curve evolution, which generally leads to large extra calculation errors. In this study, the energy field in the image is back-projected to 3-D space and decomposed into three independent components in the world coordinates centered at the iso-center of the C-arm. Then, the components from different views are composited together according to the rotation and scaling relationship of the imaging angles. The composited energy field hence is utilized as the external force to control the evolution of the vascular structure in 3-D space. As the driving force is iteratively updated according to energy in the two projection images, the non-strict matching can be effectively avoided. Also, the proposed method is very flexible, which can be composited with any energy fields such as Generalized Gradient Vector Flow (GGVF) and Potential Energy (PE) etc. Experiments demonstrate that the proposed method is very effective and robust, when using GGVF as the external force, the reconstruction RMS error can be reduced to about 0.595mm in the 3-D space.
AB - This paper presents a novel energy back-projective composition model (EBPCM) for 3-D reconstruction of the coronary arteries from two mono-plane angiographic images. A major problem with the commonly used parameter deformable model is that the predefined correspondences may become non-strict matching after the curve evolution, which generally leads to large extra calculation errors. In this study, the energy field in the image is back-projected to 3-D space and decomposed into three independent components in the world coordinates centered at the iso-center of the C-arm. Then, the components from different views are composited together according to the rotation and scaling relationship of the imaging angles. The composited energy field hence is utilized as the external force to control the evolution of the vascular structure in 3-D space. As the driving force is iteratively updated according to energy in the two projection images, the non-strict matching can be effectively avoided. Also, the proposed method is very flexible, which can be composited with any energy fields such as Generalized Gradient Vector Flow (GGVF) and Potential Energy (PE) etc. Experiments demonstrate that the proposed method is very effective and robust, when using GGVF as the external force, the reconstruction RMS error can be reduced to about 0.595mm in the 3-D space.
UR - http://www.scopus.com/inward/record.url?scp=84886575973&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2013.6610708
DO - 10.1109/EMBC.2013.6610708
M3 - Conference contribution
C2 - 24110895
AN - SCOPUS:84886575973
SN - 9781457702167
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 5151
EP - 5154
BT - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
T2 - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Y2 - 3 July 2013 through 7 July 2013
ER -