A Kinect camera based navigation system for percutaneous abdominal puncture

Deqiang Xiao, Huoling Luo, Fucang Jia, Yanfang Zhang, Yong Li, Xuejun Guo, Wei Cai, Chihua Fang, Yingfang Fan, Huimin Zheng, Qingmao Hu

科研成果: 期刊稿件文章同行评审

9 引用 (Scopus)

摘要

Percutaneous abdominal puncture is a popular interventional method for the management of abdominal tumors. Image-guided puncture can help interventional radiologists improve targeting accuracy. The second generation of Kinect was released recently, we developed an optical navigation system to investigate its feasibility for guiding percutaneous abdominal puncture, and compare its performance on needle insertion guidance with that of the first-generation Kinect. For physical-to-image registration in this system, two surfaces extracted from preoperative CT and intraoperative Kinect depth images were matched using an iterative closest point (ICP) algorithm. A 2D shape image-based correspondence searching algorithm was proposed for generating a close initial position before ICP matching. Evaluation experiments were conducted on an abdominal phantom and six beagles in vivo. For phantom study, a two-factor experiment was designed to evaluate the effect of the operator's skill and trajectory on target positioning error (TPE). A total of 36 needle punctures were tested on a Kinect for Windows version 2 (Kinect V2). The target registration error (TRE), user error, and TPE are 4.26 ± 1.94 mm, 2.92 ± 1.67 mm, and 5.23 ± 2.29 mm, respectively. No statistically significant differences in TPE regarding operator's skill and trajectory are observed. Additionally, a Kinect for Windows version 1 (Kinect V1) was tested with 12 insertions, and the TRE evaluated with the Kinect V1 is statistically significantly larger than that with the Kinect V2. For the animal experiment, fifteen artificial liver tumors were inserted guided by the navigation system. The TPE was evaluated as 6.40 ± 2.72 mm, and its lateral and longitudinal component were 4.30 ± 2.51 mm and 3.80 ± 3.11 mm, respectively. This study demonstrates that the navigation accuracy of the proposed system is acceptable, and that the second generation Kinect-based navigation is superior to the first-generation Kinect, and has potential of clinical application in percutaneous abdominal puncture.

源语言英语
页(从-至)5687-5705
页数19
期刊Physics in Medicine and Biology
61
15
DOI
出版状态已出版 - 12 7月 2016
已对外发布

指纹

探究 'A Kinect camera based navigation system for percutaneous abdominal puncture' 的科研主题。它们共同构成独一无二的指纹。

引用此