TY - JOUR
T1 - A Kinect™ camera based navigation system for percutaneous abdominal puncture
AU - Xiao, Deqiang
AU - Luo, Huoling
AU - Jia, Fucang
AU - Zhang, Yanfang
AU - Li, Yong
AU - Guo, Xuejun
AU - Cai, Wei
AU - Fang, Chihua
AU - Fan, Yingfang
AU - Zheng, Huimin
AU - Hu, Qingmao
N1 - Publisher Copyright:
© 2016 Institute of Physics and Engineering in Medicine.
PY - 2016/7/12
Y1 - 2016/7/12
N2 - Percutaneous abdominal puncture is a popular interventional method for the management of abdominal tumors. Image-guided puncture can help interventional radiologists improve targeting accuracy. The second generation of Kinect™ was released recently, we developed an optical navigation system to investigate its feasibility for guiding percutaneous abdominal puncture, and compare its performance on needle insertion guidance with that of the first-generation Kinect™. For physical-to-image registration in this system, two surfaces extracted from preoperative CT and intraoperative Kinect™ depth images were matched using an iterative closest point (ICP) algorithm. A 2D shape image-based correspondence searching algorithm was proposed for generating a close initial position before ICP matching. Evaluation experiments were conducted on an abdominal phantom and six beagles in vivo. For phantom study, a two-factor experiment was designed to evaluate the effect of the operator's skill and trajectory on target positioning error (TPE). A total of 36 needle punctures were tested on a Kinect™ for Windows version 2 (Kinect™ V2). The target registration error (TRE), user error, and TPE are 4.26 ± 1.94 mm, 2.92 ± 1.67 mm, and 5.23 ± 2.29 mm, respectively. No statistically significant differences in TPE regarding operator's skill and trajectory are observed. Additionally, a Kinect™ for Windows version 1 (Kinect™ V1) was tested with 12 insertions, and the TRE evaluated with the Kinect™ V1 is statistically significantly larger than that with the Kinect™ V2. For the animal experiment, fifteen artificial liver tumors were inserted guided by the navigation system. The TPE was evaluated as 6.40 ± 2.72 mm, and its lateral and longitudinal component were 4.30 ± 2.51 mm and 3.80 ± 3.11 mm, respectively. This study demonstrates that the navigation accuracy of the proposed system is acceptable, and that the second generation Kinect™-based navigation is superior to the first-generation Kinect™, and has potential of clinical application in percutaneous abdominal puncture.
AB - Percutaneous abdominal puncture is a popular interventional method for the management of abdominal tumors. Image-guided puncture can help interventional radiologists improve targeting accuracy. The second generation of Kinect™ was released recently, we developed an optical navigation system to investigate its feasibility for guiding percutaneous abdominal puncture, and compare its performance on needle insertion guidance with that of the first-generation Kinect™. For physical-to-image registration in this system, two surfaces extracted from preoperative CT and intraoperative Kinect™ depth images were matched using an iterative closest point (ICP) algorithm. A 2D shape image-based correspondence searching algorithm was proposed for generating a close initial position before ICP matching. Evaluation experiments were conducted on an abdominal phantom and six beagles in vivo. For phantom study, a two-factor experiment was designed to evaluate the effect of the operator's skill and trajectory on target positioning error (TPE). A total of 36 needle punctures were tested on a Kinect™ for Windows version 2 (Kinect™ V2). The target registration error (TRE), user error, and TPE are 4.26 ± 1.94 mm, 2.92 ± 1.67 mm, and 5.23 ± 2.29 mm, respectively. No statistically significant differences in TPE regarding operator's skill and trajectory are observed. Additionally, a Kinect™ for Windows version 1 (Kinect™ V1) was tested with 12 insertions, and the TRE evaluated with the Kinect™ V1 is statistically significantly larger than that with the Kinect™ V2. For the animal experiment, fifteen artificial liver tumors were inserted guided by the navigation system. The TPE was evaluated as 6.40 ± 2.72 mm, and its lateral and longitudinal component were 4.30 ± 2.51 mm and 3.80 ± 3.11 mm, respectively. This study demonstrates that the navigation accuracy of the proposed system is acceptable, and that the second generation Kinect™-based navigation is superior to the first-generation Kinect™, and has potential of clinical application in percutaneous abdominal puncture.
KW - abdominal surface matching
KW - kinect camera
KW - markerless registration
KW - needle puncture navigation
UR - http://www.scopus.com/inward/record.url?scp=84979590829&partnerID=8YFLogxK
U2 - 10.1088/0031-9155/61/15/5687
DO - 10.1088/0031-9155/61/15/5687
M3 - Article
C2 - 27401131
AN - SCOPUS:84979590829
SN - 0031-9155
VL - 61
SP - 5687
EP - 5705
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 15
ER -